CKZMX - XCEL ATF-DEXRON III/MERCON
- MSDS: CKZMX
- Manufacturer: PETROLEUM PACKERS INC
- Product Name: XCEL ATF-DEXRON III/MERCON
- National Stock Number: 9150-01-114-9968
Product Identification
Product ID:XCEL ATF-DEXRON III/MERCON
MSDS Date:06/01/1997
FSC:9150
NIIN:01-114-9968
Status Code:A
MSDS Number: CKZMX
Responsible Party
TAMPA, FL 33605-6710
US
Emergency Phone: 800-424-9300
Info Phone: 813-248-1988;800-424-8802
Cage: 7A776
Contractor
Telephone: 813-248-1988
Cage: TO061
Ingredients
MIXTURE - LUBRICATING OIL
Hazards
LD50 LC50 Mixture:NO DATA PROVIDED BY MANUFACTURER
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:POSSIBLE SKIN IRRITANT UPON REPEATED
OR PROLONGED CONTACT.
Explanation of Carcinogenicity:NO DATA PROVIDED BY MANUFACTURER.
Effects of Overexposure:POSSIBLE SKIN IRRITANT UPON REPEATED OR
PROLONGED CONTACT.
Medical Cond Aggravated by Exposure:NO DATA PROVIDED BY MANUFACTURER.
First Aid
First Aid:INHALATION: REMOVE FROM EXPOSURE TO INCIDENTIAL FUMES AND
PROVIDE RESPIRATORY SUPPORT IF NECESSARY. DERMAL: WASH WITH SOAP
AND WATER, UNTIL ALL TRACES OF MATERIAL ARE REMOVED. EYES: FLUSH
WITH LARGE V OLUMES OF WATER. INGESTION: DO NOT INDUCE VOMITING.
SEEK MEDICAL AID. INJECTION: SEEK MEDICAL AID. NOTE: FOLLOWING
INGESTION, AT A SAYBOLT VISCOSITY OF ~175SUS, (100F), THE RISK OF
ASPIRATION INTO THE LUNGS IS REDUCED. REMOVE ALL MATERIAL BY
EMESIS OR LAVAGE. SUBCUTANEOUS OR INTRAMUSCULAR INJECTION REQUIRES
PROMPT SURGICAL DEBRIDEMENT. IF NOT FAMILIAR WITH TECHNIQUE, SEEK
SKILLED ADVICE.
Fire Fighting
Flash Point Method:COC
Flash Point:=186.C, 366.8F
Extinguishing Media:CO2, DRY CHEMICAL, FOAM, WATER FOG
Fire Fighting Procedures:NONE
Unusual Fire/Explosion Hazard:WATER MAY CAUSE FROTHING
Accidental Release
Spill Release Procedures:NO DATA PROVIDED BY MANUFACTURER
Neutralizing Agent:NO DATA PROVIDED BY MANUFACTURER
Handling
Handling and Storage Precautions:NO DATA PROVIDED BY MANUFACTURER
Other Precautions:MAY CAUSE SKIN IRRITATION. WASH AREA WITH SOAP AND
WATER. FLUSH EYES WITH WATER. DO NOT INDUCE VOMITING. SEEK MEDICAL
ADVICE.
Exposure Controls
Respiratory Protection:NO DATA PROVIDED BY MANUFACTURER
Ventilation:NO DATA PROVIDED BY MANUFACTURER
Protective Gloves:NO DATA PROVIDED BY MANUFACTURER
Eye Protection:NO DATA PROVIDED BY MANUFACTURER
Other Protective Equipment:NO DATA PROVIDED BY MANUFACTURER
Work Hygienic Practices:NO DATA PROVIDED BY MANUFACTURER
Supplemental Safety and Health
SYNONYMS: TRANSMISSION FLUID
Chemical Properties
HCC:V6
Disposal
Waste Disposal Methods:NO DATA PROVIDED BY MANUFACTURER.
Toxicology
Toxicological Information:CARCINOGEN: NO. ANIMAL CARCINOGEN: NO.
SUSTPECT CARCINOGEN: NO. MUTAGEN: NO. HIGHLY TOXIC: NO. CORROSIVE:
NO. SNESITIZER: NO. TERATOGEN: NO. TOXIC: NO. IRRITANT: NO
(POSSIBLE SKIN IRRITATION UPON REP EATED OR PROLONGED CONTACT).
Other Information
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ecology
Ecological:NO DATA PROVIDED BY MANUFACTURER
Transport
Transport Information:DOT/UN SHIPPING NAME: PETROLEUM LUBRICATING OIL.
DOT/HAZARD CLASS: NON-HAZARDOUS. DOT/UN HAZARD IDENTIFICATION
NUMBER: NONE ASSIGNED. DOT PLACARD: N/D. CARGO FIRE COMPATIBILITY:
N/D.
Regulatory
SARA Title III Information:SECTION 313 TOXIC CHEMICALS: THIS PRODUCT
DOES NOT CONTAIN TOXIC CHEMICALS OF SECTION 313 OF TITLE III OF
SUPERFUND AMENDMENTS AND RE-AUTHORIZATION ACT OF 1996 (SARA) AND 40
CFR PART 372. SECTION 311 HAZARD CATEGORIES: NOT APPLICABLE: YES;
ACUTE (IMMEDIATE HEALTH HAZARD): NO, CHRONIC (DELAYED HEALTH
HAZARD): NO; FIRE HAZARD: NO; SUDDEN RELEASE OF PRESSURE HAZARD:
NO; REACTIVE HAZARD: NO.
Federal Regulatory Information:NO DATA PROVIDED BY MANUFACTURER
State Regulatory Information:NO DATA PROVIDED BY MANUFACTURER